PVIS PV Installer Specialist — Exam Overview
Quick Facts
PVIS — PV Installer Specialist (PVIS) Board Certification — is a NABCEP (North American Board of Certified Energy Practitioners) credential examined against the Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS. Domains and owner weights: Develop safety plan (8%); Safeguard against hazards (10%); Install raceways (7%); Install electrical equipment (8%); Install DC PV system conductors (8%); Install AC PV system conductors (8%); Install grounding & bonding (10%); Complete utility interconnection point (8%); Install system monitoring, control, and communication hardware (3%); Install battery equipment (7%); Install ground-mounted structure (5%); Install building-mounted system (8%); Install PV modules (8%). The thirteen printed task weights sum to 98% as published in the JTA; grounding & bonding and safeguarding against hazards carry the largest single weights (10% each). Owner fees: Application $125 / Exam $375 / Re-exam $275 / Recertification $390 (NABCEP Fees page). NABCEP does not publish a pass mark for this credential in its JTA; none is asserted here. This Study4Pass practice bank contains 80 original practice questions aligned to that blueprint.
Who this exam is for
Experienced PV installers who build systems hands-on — safety planning, hazard control, raceways, DC and AC wiring, grounding, interconnection, batteries, structures and modules — and are preparing for the NABCEP PV Installer Specialist (PVIS) Board Certification.
Exam Domains
Develop safety plan — 8%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering building the site-specific safety plan — hazard assessment, JHAs, emergency response and stop-work authority — before installation begins. Owner weight: 8%. Key skills: Hazard assessment; Job hazard analysis; Stop-work authority; Emergency planning; Heat illness prevention.
Safeguard against hazards — 10%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering protecting the crew from the hazards of live PV work: shock, arc, falls, ladders and utility conductors. Owner weight: 10%. Key skills: Energised-array awareness; Voltage verification; PPE and insulated tools; LOTO with live DC sources; Ladder and utility-line safety.
Install raceways — 7%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering installing raceways that protect conductors — correct fill, bends, supports and sealed transitions. Owner weight: 7%. Key skills: Conduit types and fill; Bending and support; Sealing transitions; Conductor protection.
Install electrical equipment — 8%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering mounting and connecting electrical equipment to its listing: clearances, terminations, breakers and labels. Owner weight: 8%. Key skills: Inverter and disconnect mounting; Clearances; Terminal landing and torque; Backfed breaker placement and labels.
Install DC PV system conductors — 8%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering installing DC array wiring: rated conductors, verified polarity, listed connectors and protected routing. Owner weight: 8%. Key skills: PV wire selection; Polarity and voltage checks; Listed connector mating; Lead support and protection.
Install AC PV system conductors — 8%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering installing the AC output circuit from inverter to interconnection with correct sizing, terminations and checks. Owner weight: 8%. Key skills: AC sizing from inverter output; Voltage rise; Neutral/ground separation; Energisation checks.
Install grounding & bonding — 10%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering building the grounding and bonding system: listed bonding hardware, electrode connections and verified continuity. Owner weight: 10%. Key skills: Bonding of frames and racking; Grounding electrode system; Jumpers and continuity; Corrosion-aware hardware.
Complete utility interconnection point — 8%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering completing the utility interconnection point exactly as approved, through inspection to permission to operate. Owner weight: 8%. Key skills: Point-of-interconnection checks; Supply-side tap rules; PTO discipline; Utility metering requirements.
Install system monitoring, control, and communication hardware — 3%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering installing monitoring hardware so production data is accurate and flowing before the crew leaves. Owner weight: 3%. Key skills: CT orientation; Gateway connection; Live data verification.
Install battery equipment — 7%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering installing battery equipment: structure, protection, backup circuits and control wiring. Owner weight: 7%. Key skills: Battery mounting and clearances; DC protection; Backup panel configuration; BMS communications.
Install ground-mounted structure — 5%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering building ground-mount structures on verified foundations, layout and buried services. Owner weight: 5%. Key skills: Utility locates; Post setting and tolerances; Foundations and frost; Trenching and burial depth.
Install building-mounted system — 8%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering installing building-mounted arrays into real framing with flashed penetrations and aligned racking. Owner weight: 8%. Key skills: Rafter location; Flashing every penetration; Standoff and rail alignment; Fall-safe work methods.
Install PV modules — 8%
One of the 13 domains in the owner blueprint for the PVIS examination (Photovoltaic Specialists: Job Task Analysis (September 2017, V. 02.21) — the combined Specialist JTA published by NABCEP for PVDS, PVIS and PVCMS), covering placing and securing modules without damage, in listed clamp zones, with dressed leads and recorded serials. Owner weight: 8%. Key skills: Module handling; Model and condition verification; Clamp zones and torque; Lead dressing and records.
Preparing for PVIS
Work through the practice questions in study mode first, read every explanation, then switch to timed practice. Weight your revision by the domain weightings above and revisit the topics you score lowest on until your practice scores are consistent.
Write Your Review on PVIS PV Installer Specialist
PVIS Customer Reviews
No reviews yet
Be the first to share your experience with this exam.