CSITMS Certified Sprinkler Inspection, Testing, and Maintenance Specialist for Facility Managers โ Exam Overview
Quick Facts
The Certified Sprinkler Inspection, Testing, and Maintenance Specialist for Facility Managers (CSITMS) exam contains 100 multiple-choice questions with a 3-hour time limit. It is an open-book exam based on the 2014 edition of NFPA 25 and is available in English only. The Program Overview describes its domain percentages as approximate, and NFPA does not publish a passing score or a price in the overview, so neither figure is stated here.
Who this exam is for
Facility managers and building operations professionals who oversee the inspection, testing, and maintenance of water-based fire protection systems in their facilities. It suits managers who direct in-house staff or contractors performing NFPA 25 work and who carry the owner's responsibilities for system readiness, records, and impairments.
Exam Domains
General Requirements โ 18%
Covers the foundations of NFPA 25 (2014): the scope of the standard, the property owner's retained responsibilities even when ITM is contracted out, and the requirement for qualified personnel. It also covers records and reports, providing access to components, maintaining heat against freezing, evaluating changes in occupancy or hazard, and the distinction between deficiencies and impairments.
Inspection โ 24%
Covers the visual inspection programme for sprinklers, piping, fittings, hangers, and control valves, including weekly checks of sealed valves and dry-system gauges and monthly checks of locked or supervised valves, wet-system gauges, alarm valves, and fire department connections. It also covers quarterly alarm and supervisory device inspections, annual sprinkler and piping inspections, fire pump house inspections, and the disposition of painted, corroded, or loaded sprinklers.
Testing โ 22%
Covers functional testing, including the annual main drain test and investigation of residual pressure drops over 10 percent, quarterly waterflow alarm tests through the inspector's test connection, and dry-pipe priming level and trip testing on quarterly, annual, and three-year cycles. It also covers weekly fire pump churn tests, the annual pump flow test at churn, rated, and 150 percent flows, five-year gauge and private main tests, annual antifreeze and backflow forward-flow tests, and age-based sprinkler sample testing.
Maintenance โ 22%
Covers keeping systems in operating condition: annual exercising and lubrication of control valves, like-for-like sprinkler replacement matching K-factor and temperature rating, and maintaining the spare sprinkler stock and wrench. It also covers resetting and internally inspecting dry valves after operation, correcting deficiencies promptly, pressure-reducing valve test cycles, antifreeze correction, diesel pump upkeep, freeze-season preparation, and restoring valves and supervision after work.
Obstruction Investigation & Impairments โ 14%
Covers the five-year internal obstruction investigation, the findings that trigger one sooner, such as foreign material in tests, plugged devices, and signs of microbiologically influenced corrosion, and the flushing or cleaning that follows a confirmed obstruction. It also covers Chapter 15 impairment procedures: the impairment coordinator, the red tag system, notifications to the AHJ, fire department, alarm company, and insurer, prior authorisation of planned impairments, and evacuation or fire watch when an outage exceeds 10 hours in a 24-hour period.
Preparing for CSITMS
Work through the practice questions in study mode first, read every explanation, then switch to timed practice. Weight your revision by the domain weightings above and revisit the topics you score lowest on until your practice scores are consistent.
Write Your Review on CSITMS Certified Sprinkler Inspection, Testing, and Maintenance Specialist for Facility Managers
CSITMS Customer Reviews
No reviews yet
Be the first to share your experience with this exam.