What to study for each ISO-13485-Lead-Implementer domain
Domain 1: Fundamental principles and concepts of a Medical Devices Quality Management System (MDQMS)
This domain covers the fundamental ideas behind a medical devices QMS: what a medical device is, including implantable and sterile devices, the manufacturer role, the regulatory basis of ISO 13485, risk management throughout the system, the process approach, and the medical device file.
Key skills
Learners can explain core MDQMS concepts and why regulatory compliance and risk management shape every part of the system.
Domain 2: Medical Devices Quality Management System (MDQMS)
This domain covers the requirements of ISO 13485 in Clauses 4 to 8: QMS documentation and the quality manual, management responsibility, competence and work environment, product realization including design, purchasing, and production, and measurement, analysis, and improvement including complaints and CAPA.
Key skills
Learners can map ISO 13485 requirements to the processes, procedures, and records an MDQMS must operate and maintain.
Domain 3: Planning a MDQMS implementation based on ISO 13485
This domain covers planning an MDQMS implementation: understanding the organization, its devices, and its regulatory landscape, gap analysis against ISO 13485, defining scope with justified non-applicability, planning outsourced process control, risk management, documentation, and competence, and building the implementation plan.
Key skills
Learners can initiate and plan an MDQMS implementation with a defined scope, regulatory mapping, and a resourced route to certification readiness.
Domain 4: Implementing a MDQMS based on ISO 13485
This domain covers implementing the MDQMS: putting documented processes into operation, design and development controls from inputs to verification, validation, and transfer, supplier and purchasing controls, process and software validation, and identification, traceability, and preservation of product.
Key skills
Learners can implement MDQMS controls for design, purchasing, and production in accordance with ISO 13485 and generate the records that evidence them.
Domain 5: Performance evaluation, monitoring and measurement of a MDQMS based on ISO 13485
This domain covers evaluating MDQMS performance: monitoring processes and product, the feedback system, complaint handling and advisory notices, control of monitoring and measuring equipment, the internal audit programme, data analysis, and management review inputs and outputs.
Key skills
Learners can operate feedback, complaint, audit, and review processes that show whether the MDQMS remains suitable, adequate, and effective.
Domain 6: Continual improvement of a MDQMS based on ISO 13485
This domain covers continual improvement of the MDQMS: correction versus corrective and preventive action, root cause analysis, CAPA effectiveness and adverse-effect verification, complaint trend analysis, controlled change, post-market surveillance, and keeping the risk management file current.
Key skills
Learners can run a risk-based CAPA system and use post-market information to improve device safety, performance, and QMS effectiveness.
Domain 7: Preparing for a MDQMS certification audit
This domain covers preparation for an MDQMS certification audit: the purpose of Stage 1 and Stage 2 audits, readiness evidence such as a completed internal audit and management review, major and minor nonconformities, responding to findings, choosing an accredited certification body, and surveillance and recertification.
Key skills
Learners can prepare the organization, its people, and its device evidence for Stage 1 and Stage 2 certification audits and the cycle that follows.