What to study for each CFAITMS domain
General Knowledge
Covers the fundamentals of fire alarm and signaling systems under NFPA 72, including system types and components, initiating devices and notification appliances, control units, and power supplies. It also covers alarm, supervisory, and trouble signals, supervising station reporting, and the roles of qualified personnel and the authority having jurisdiction.
Key skills
Identifying system components and signal types, explaining secondary power requirements, and describing system functions and responsibilities.
Inspection
Covers visual inspection of fire alarm systems to Table 14.3.1 of NFPA 72, including inspection frequencies for control equipment, batteries, initiating devices, notification appliances, and transmitters. It also covers recognizing deficiencies such as obstructed, damaged, painted, or missing devices and changes in occupancy or layout that affect performance.
Key skills
Applying visual inspection frequencies, spotting field deficiencies, and documenting inspection findings for correction.
Testing
Covers functional testing to Table 14.4.2.2 of NFPA 72, including annual testing of initiating devices and notification appliances, smoke detector sensitivity testing, battery testing, and testing of interfaces and fire safety functions. It also covers correct test methods, supervising station notification during tests, and retesting after repair or replacement.
Key skills
Applying test frequencies and listed test methods, verifying complete alarm sequences and interfaces, and documenting test results and failures.
Maintenance
Covers preventive maintenance that keeps devices clean, adjusted, and within their listed limits, including detector cleaning and replacement of end-of-life components such as batteries. It also covers impairment handling: notification, tagging, compensating measures such as fire watch for extended outages, and verified restoration to service.
Key skills
Planning preventive maintenance, managing planned and emergency impairments, and verifying restoration after maintenance work.
Records
Covers the documentation NFPA 72 requires for fire alarm systems, including the record of completion, inspection and test records with device-level results and deficiencies, and records of impairments, corrections, and system changes. It also covers retention until the next test and for one year thereafter, permanent records kept for the life of the system, and availability of records to the owner and the authority having jurisdiction.
Key skills
Completing compliant ITM records, applying retention rules, closing out deficiencies on paper, and keeping system documentation current.