This free ISO-14971-LA demo gives you 10 questions and answers from the full 85-question Study4Pass bank, with Ask AI on every question and no signup. Premium unlocks all 85 questions in PDF and the test engine, with plans from $29.70 USD, instant access and 90 days of free updates — the Black Friday offer of 55% off is now active until December 15.
What to study for each ISO-14971-LA domain
Domain 1: ISO 14971 fundamentals and the risk management framework
This domain covers the foundations of ISO 14971:2019: its scope across the medical device life cycle and the core terms hazard, hazardous situation, harm, and risk. It also covers the general requirements of the process, top management responsibilities, the policy for risk acceptability criteria, personnel competence, the risk management plan, and the risk management file.
Key skills: Learners can explain the ISO 14971 process end to end and identify the plan, policy, responsibilities, and file evidence an audit must find.
Domain 2: Risk analysis and risk evaluation
This domain covers risk analysis: defining intended use and reasonably foreseeable misuse, identifying safety-related characteristics, hazards, and hazardous situations, and estimating probability and severity. It also covers risk evaluation, in which each estimated risk is compared with the manufacturer's acceptability criteria to decide whether control is required.
Key skills: Learners can trace a hazard through analysis to an evaluated risk and judge whether the estimation basis and criteria were properly applied.
Domain 3: Risk control and evaluation of residual risk
This domain covers risk control: the priority order of inherent safety by design, protective measures, and information for safety, and verifying each control's implementation and effectiveness. It also covers checking controls for new hazards, evaluating residual and overall residual risk, benefit-risk analysis, and disclosing significant residual risks.
Key skills: Learners can audit whether controls follow the required priority, are verified, and leave residual risks that are acceptable or justified by benefit-risk analysis.
Domain 4: Risk management review and production and post-production activities
This domain covers the risk management review performed before commercial distribution, confirming the plan was executed and overall residual risk is acceptable. It also covers collecting and reviewing production and post-production information, including complaints, adverse events, and similar-device experience, and acting when risks are no longer acceptable.
Key skills: Learners can audit the pre-release review and test whether post-production information genuinely feeds back into risk decisions.
Domain 5: Auditing a medical device risk management system
This domain covers applying lead auditor skills to ISO 14971: preparing the audit, sampling risk management files, and interviewing across design, production, and post-market functions. It also covers verifying controls in production, testing complaint handling, wording findings against requirements, and managing the audit team and opening meeting.
Key skills: Learners can plan and lead an ISO 14971 audit that traces hazards through the file and rests every finding on verified objective evidence.
Domain 6: Regulatory context, audit reporting, and corrective action
This domain covers the setting in which ISO 14971 audits operate: how regulators reference the standard, and how audit reports present scope, criteria, findings, and conclusions. It also covers corrective action and follow-up verification, escalation of serious safety concerns, confidentiality, and recording disagreements, while keeping audit conclusions about process conformity rather than device approval.
Key skills: Learners can report and close ISO 14971 audits professionally, verify corrective action effectiveness, and escalate safety concerns through the right channels.