Free IDIX – Interior Design Implementation Exam Practice Test Question

Free demo downloads

Loading demo links...

Showing 1–10 of 10 questions

Question 1 (Codes and Life Safety)

A tenant improvement for a business occupancy has a calculated occupant load of 240. The space is sprinklered throughout. How many exits are required at minimum?

Select an option, then click Submit answer.

  • ○ Two exits
  • ○ Three exits
  • ○ One exit if travel distance is under 75 feet
  • ○ Four exits

Ask AI for More Explanation

— your own AI account, opens inside the app

About the IDIX Free Practice Test

This page holds a free practice test for the Interior Design Implementation Exam (IDIX) from CIDQ, one of the three sections required for the NCIDQ Certificate. You will find 10 free questions, drawn from the full Study4Pass practice set of 80 questions for this exam. The questions follow the same topic balance as the real exam: Codes and Life Safety; Integration and FF&E; Construction Documents; Consultant Drawing Coordination; Construction Specifications and Schedules.

How to use this IDIX free practice test

Pick an answer for each question and check it straight away — the correct answer and a full explanation appear under the question. There is no time limit and nothing to sign up for. When an explanation is not enough, use Ask AI: this is an AI-Enabled practice test, and Ask AI explains the concept behind the question in plain language. Ready for more? The full 80-question set adds a timed Exam Simulation mode, topic training for your weak areas, and a flagged-question review.

What to study for each IDIX domain

Codes and Life Safety

Egress requirements (number of exits, occupant load, travel distance, common path, exit separation and signage), fire-resistance ratings for corridors, partitions and door assemblies, interior finish flame spread and smoke development classes, safety glazing in hazardous locations, accessibility requirements for fixtures, handrails and clearances, and fireblocking and draftstopping — applied with the health, safety, and welfare emphasis that governs the IDIX exam.

Key skills

Occupant load and exit counts; travel distance and common path; corridor and door fire ratings; finish flame spread classes; safety glazing; accessible fixture and handrail requirements; fireblocking and draftstopping

Integration and FF&E

Integrating furniture, fixtures and equipment with building systems: coordinating power and data with fixed and systems furniture, lighting layouts on the reflected ceiling plan, plumbing fixtures with accessible clearances, operable partitions with structure and acoustics, window treatments with pockets and motorization, signage with accessibility requirements, appliance services in kitchenettes, and flammability and life-safety checks on FF&E selections.

Key skills

Power/data coordination with FF&E; ceiling and lighting integration; accessible plumbing fixture integration; operable partitions; window treatment provisions; accessible signage; appliance service coordination; FF&E flammability compliance

Construction Documents

Producing a complete, coordinated construction document set: floor plans as the key reference, partition types and tags, reflected ceiling plans, interior elevations, sections and enlarged plans, details and scales, dimensioning conventions, door/finish/fixture schedules that agree with the plans, keynotes and legends, demolition versus new-work scope, graphic scales, title block and revision control, and shop drawing review — the largest domain, reflecting the IDIX focus on the construction documentation phase.

Key skills

Floor plan coordination; partition types; reflected ceiling plans; elevations, sections and details; dimensioning conventions; schedule accuracy; keynotes and legends; demolition/new work scope; document control and revisions; submittal review

Consultant Drawing Coordination

Coordinating the interior documents with consultant drawings: structural support for openings and heavy elements, mechanical duct clearances versus ceiling heights, a single shared lighting fixture schedule, AV and security rough-in, plumbing relocations, food-service equipment requirements, sprinkler coverage versus ceiling design, acoustic assembly changes, site finished-floor levels, and version control of shared background files.

Key skills

Structural coordination; mechanical clearances; shared fixture schedules; AV/security rough-in; plumbing coordination; equipment service requirements; sprinkler coordination; background file version control

Construction Specifications and Schedules

Specifying the work with MasterFormat: Division 01 general requirements versus technical sections, performance, reference, descriptive and proprietary specification methods and substitutions, finish legends and schedules, door hardware sets, equipment schedules carrying MEP service data, FF&E specifications tied to the furniture plan, and reconciling schedules, legends and specifications before bidding.

Key skills

MasterFormat organization; Division 01 vs technical sections; specification methods; finish legends and schedules; hardware sets; equipment schedules; FF&E specifications; pre-bid reconciliation

IDIX practice test — quick questions

Is this IDIX practice test free?

Yes — the 10 questions on this page are completely free, with no signup and no payment details needed.

How many questions are in the full IDIX set?

80 questions. The 10 free questions above are a sample of that full set, in the same style and topic balance.

Does the free test show the answers?

Yes — every question shows the correct answer with an explanation, and Ask AI can explain the concept behind a question in plain words if you want to go deeper.