Luminous flux, the total light output of a lamp, is measured in which unit?
Select an option, then click Submit answer.
- ○ Lumens
- ○ Candela
- ○ Lux
- ○ Footcandles
Loading demo links...
Showing 1–10 of 10 questions
Luminous flux, the total light output of a lamp, is measured in which unit?
Select an option, then click Submit answer.
What does luminous efficacy describe?
Select an option, then click Submit answer.
A lamp producing 8,000 lumens while consuming 80 W (including driver losses) has an efficacy of what?
Select an option, then click Submit answer.
Which term describes light that reaches a surface, expressed as lumens per unit area?
Select an option, then click Submit answer.
Luminance is best understood as what?
Select an option, then click Submit answer.
Which statement about the inverse square law is correct?
Select an option, then click Submit answer.
Why do system watts, not lamp watts alone, matter when stating lighting efficiency?
Select an option, then click Submit answer.
Which TWO quantities together determine how bright a task will appear? (Choose two.)
Select all that apply, then click Submit answer.
One footcandle equals approximately how many lux?
Select an option, then click Submit answer.
Which TWO factors are combined in the light loss factor (LLF)? (Choose two.)
Select all that apply, then click Submit answer.
This page holds a free practice test for the Certified Lighting Efficiency Professional (CLEP) certification from AEE. You will find 10 free questions, drawn from the full Study4Pass practice set of 80 questions for this exam. The questions follow the same topic balance as the real exam: Language of Light and Lighting Efficiency; Lighting Quantity and Quality Fundamentals; Color, Visibility and Health; Traditional Light Source Lamps and Ballasts and their Operating Characteristics; LED Technology and its Operating Characteristics; Lighting Maintenance and Environmental Safety; Lighting Controls; Lighting Audits; Lighting Photometrics, Reports and IES files; Lighting Calculations; Financial Analysis Metrics and Calculations.
Pick an answer for each question and check it straight away — the correct answer and a full explanation appear under the question. There is no time limit and nothing to sign up for. When an explanation is not enough, use Ask AI: this is an AI-Enabled practice test, and Ask AI explains the concept behind the question in plain language. Ready for more? The full 80-question set adds a timed Exam Simulation mode, topic training for your weak areas, and a flagged-question review.
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering the vocabulary and physics of light: lumens, candela, illuminance and luminance, efficacy, the inverse square law and system watts.
Lumens, candela, lux and footcandles; Efficacy; Inverse square law; System watts
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering illuminance units and recommended levels, coefficient of utilization, light loss factors, photometric distribution, uniformity and spacing criteria.
Lux-footcandle conversion; Recommended illuminance; CU and LLF; Distribution and uniformity; Spacing criterion
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering colour temperature, colour rendering including R9, spectra, glare, visibility factors, circadian effects and flicker.
CCT; CRI and R9; Spectral distribution; Glare control; Circadian effects; Stroboscopic flicker
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering incandescent, fluorescent and HID lamp operation, ballast function and types, starting characteristics and efficacy of legacy sources.
Ballast function; Magnetic vs electronic ballasts; HID warm-up and restrike; Filament lamp losses
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering LED operation and thermal management, drivers, L70 life, LM-80/TM-21, dimming compatibility and retrofit photometrics.
Junction temperature; Drivers; L70 and TM-21; Dimming compatibility; Retrofit photometrics
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering group relamping, luminaire cleaning, light-loss recovery and the safe handling and disposal of mercury-containing lamps.
Group relamping; Cleaning and dirt depreciation; Mercury lamp disposal
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering occupancy and vacancy sensing, daylight harvesting, scheduling, bi-level control, sensor technologies and integration with building automation.
Occupancy vs vacancy sensors; Daylight dimming; Scheduling and sweep-off; Bi-level control; Astronomic clocks
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering lighting inventories, measured versus recommended light levels, operating hours by space and the data a credible retrofit analysis requires.
Fixture inventories; Light-level surveys; Hours by space type
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering IES photometric files, LM-79 and LM-80 reports, candela distributions, zonal lumens and luminaire efficiency.
IES LM-63 files; LM-79 reports; LM-80 data; Polar curves; Zonal lumens; Light output ratio
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering the lumen method, point-by-point calculations, room cavity ratio, lighting power density, connected load and savings calculations.
Lumen method; Point-by-point; Room cavity ratio; LPD; Load and savings arithmetic
One of the 11 domains in the eleven sections of AEE's CLEP Body of Knowledge for the CLEP examination, covering simple payback, demand and energy savings valuation, NPV, incentives and life-cycle costing of lighting projects.
Payback; Energy plus demand savings; NPV; Rebates; Life-cycle cost
Yes — the 10 questions on this page are completely free, with no signup and no payment details needed.
80 questions. The 10 free questions above are a sample of that full set, in the same style and topic balance.
Yes — every question shows the correct answer with an explanation, and Ask AI can explain the concept behind a question in plain words if you want to go deeper.