300-180 Troubleshooting Cisco Data Center Infrastructure

Loading demo links...

Showing 10–12 of 15 questions

Question 10

Refer to the exhibit.

You configure an MTU on an Ethernet port profile. Where is the MTU value unsupported?

Select an option, then click Submit answer.

  • pNIC on the VEM

  • vNIC of the VEM

  • VMware vCenter

  • Cisco Nexus 1000V Series 1000V Switch

Question 11

Refer to the exhibit.

VM-1 and VM-3 are in different EPGs but in the same BD. Which statement about the communication between VM-1 and VM-3 is true?

Select an option, then click Submit answer.

  • The flow uses encapsulated VLANs.

  • The flow must transverse the spine.

  • The packet must transverse a Layer 3 interface.

  • The flow stays local to the leaf switch.

Question 12

A customer is configuring an upstream disjoint Layer 2 network in a Cisco UCS domain So far they have configured the following:

Fabric Interconnects are in switching mode.

There is symmetrical configuration for high availability.

There are no overlapping VLANs.

Each vNIC is communicating with one disjoint Layer 2 network.

After validating the above, the customer is still having issues with network connectivity.

What is the issue?

Select an option, then click Submit answer.

  • The fabric interconnect must be in end-host made for a disjoint Layer 2 network.

  • The vNIC configuration is incorrect and must communicate with two or more disjoint layer 2 networks.

  • Overlapping VLANs are allowed in a disjoint Layer 2 network.

  • Asymmetrical configuration for high availability needs to be configured.